PROTECTION RELAY EXPERIMENT TRAINER
Features:
- Experiment projects are complete, experiment content is rich, design is reasonable, which are beneficial to broaden the students’ knowledge.
- Experimental device has excellent compatibility and scalability. Experimental installations adopt platform design, laboratory modules using component design School can based on teaching demand choose experimental module freely. If need to add depth and breadth of experiments, user simply need to add components.
- Experimental Device has strong intuitionist. Each relay is the abdomen – installed on the panel surface, students can clearly see the action of every relay, and are convenient to set relay values. At the same time, the relays and other components electrical diagrams of are painting on each panel, which are complete and consistent teaching materials, can help students understand the book knowledge, improve the experimental results.
- The experiments are strong package, the AC-DC power supply, instrumentation, relay and experimental connecting wire in experiment all fully equipped, school do not need to add any equipment to complete the experimental content.
- Experiment has authenticity. The relays used in experiment are relays which are currently using on-site power system, and better reflect the status of the power system, and lay a good foundation to engage in design, installation, debugging, maintenance and other work to for students after graduation for protection system.
- Structure is reasonable. The whole structure adopt a three-tier structure, panel ranking according to the actual line with the flow, experimental function block is clarity, carefully designing improve experimenter’s understanding of the system, wiring facilitate and the efficiency of the experiment.
- The experiment device has perfect protection measures. The device provides leakage circuit breakers and other physical security protection measures, Experimental lead adopts fully enclosed plastic wire to ensure the students’ operation safety. Various instruments and power supplies all have a perfect protection function.
Technical Specification:
1. Signal Relay
– Voltage: 220V
– NO Contact: 2 sets
2. Adjustable Single Phase
– Voltage: 0 – 240V
– Current: 1A
3. Bridge Rectifier
– Voltage: 1000V
– Current: 35A
4. Universal Change Over Switch
– Rated Current: 20A
– NO Contact: 4 sets
5. Simulate Switch Board
– Rated voltage: 240VAC
– Push Button: x 3 units
6. Current Relay
– Current: 1.25 to 5A
– NO Contact: 1 set
7. Negative Sequence Relay
– Input voltage: L1, L2 & L3
– Voltage: 220VDC
8. Time Delay Contractor
– Coil Voltage: 240VAC
– Contact: NO & NC
– Time: 0….60seconds
9. Intermediate Relay
– Voltage: 220VDC
– Trigger Current: 1A
– NO Contact: 2 sets
– NC Contact: 2 sets
10. Phase Analyzer
– Input: L1, L2 & L3
– To check phase voltage in correct / Incorrect sequence
11. Adjustable Three Phase
– Protection Fuse: 2A x 3 units
– Pilot Lamps L1, L2 & L3
– Fault Current Circuit Breaker 3 Poles
– Output: 0…..240VAC x 3 units
– Input: AC415V, 50Hz 3-phase
12. Timer Relay
– Voltage: 220VDC
– Time: 0.1s to 1.5s
– NO Contact: 2 sets
– NC Contact: 2 sets
13. Low Voltage Relay
– Voltage: 40V to 160V
– NO Contact: 1 set
– NC Contact: 1 set
14. Impulse Relay
– Voltage: 220VDC
– Current: 0.16A
– NO Contact: 1 set
– NC Contact: 1 set
15. Synchronous Detector
– Voltage: 220VDC
– Voltage: Compare: 110VAC
– NO Contact: 1 set
– NC Contact: 1 set
16. Flashing Relay
– Voltage: 220VDC
– NO Contact: 2 sets
17. Overload Relay
– Current: 8A to 16A
– NO Contact: 2 sets
18. Electronic Timer
– Start, stop and reset function
19. Contactor
– Voltage: 220VDC
– NO Contact: 2 sets
– NC Contact: 2 sets
20. Rheostat 100Ω/1kΩ
– Rheostat 1kΩ/100W
– Rheostat 100Ω/100W
21. Indicator and Buzzer
– Lamp Voltage: 240VAC
– Buzzer Voltage: 240VAC
22. Alarm Indicator
– Voltage: 240VDC
23. AC Voltmeter
– Range: 300V & 500V
24. AC Ammeter
– Range: 5A & 20A
25. DC Current & Voltmeter
– Voltage Range: 300V
– Current Range: 10A
26. Three Phase Bridge Rectifier
– Three Phase Bridge Rectifier
– Maximum Voltage: 400VAC
– Maximum Current: 10A
27. Fault Current Circuit Breaker
– Protection Fuse: 2A x 3 units
– Pilot Lamps L1, L2 & L3
– Fault Current Circuit Breaker 3poles
– Input: AC 415V,50Hz 3-Phase
28. Resistive Load
– Compose of three resistances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase
– Max Power: 1200 watt
– 380/220Volt (Star/Delta)
Experiment Coverage:
- Current relay
- Voltage relay
- Electromagnetic Time relay
- Intermediate relay
- Signal relay
- Flashlight relay
- Three phase reclosing device
- Rectifier direction characteristic impedance relay
- Differential relay
- Power direction relay
- Anti-time over current relays characteristics
- 67-10KV Over-current protection circuit
- Low voltage start over-current protection and overload protection
- Break control loop with lighting surveillance
- Automatic reclosing accelerated protection
- Automatic reclosing after accelerate protection circuit
- Power direction over current protection
- Distance protection and direction stage-protection setting
- Overcurrent protection and automatic reclosing of three-phase experiment and evaluation
- Low voltage start over-current protection and automatic reclosing (after accelerating) integrative experiment and evaluation
- Current and Voltage instantaneous protection and automatic re-closing (after accelerating) integrative experiment and evaluation
- Overvoltage protection and automatic reclosing (after accelerating) integrative experiment and evaluation
- Three-phase current protection and automatic re-closing (after accelerating) integrative experiment and evaluation
- Over-current protection and automatic reclosing (accelerated) integrative experiment and evaluation
- Low voltage start over-current protection and automatic reclosing (accelerated) integrative experiment and evaluation
- Current at resia Voltage Protection and automatic reclosing (accelerated) integrative experiment and evaluation
- Overvoltage protection and automatic reclosing (accelerated) integrative experiment and evaluation
- Three-phase current protection and automatic reclosing (accelerated) integrated with the experimental evaluation
Accessories:
- U-link
- For connecting junction point
- 50 units
- Safety connecting lead
- The set consist of 50 leads in 3 different coded colors and lengths chosen to allow the realization of all experiment.
- Leads are capable of 32A current safety plugs.
- Safety terminal socket: 4mm.
- Red, 90cm (10 units)
- Yellow, 30cm (10 units)
- Blue, 60cm (20 units)
- Black, 90cm (10 units)
- Vertical Frame
- High level: DIN standard A4 with two shelves
- Material: Aluminium
- Side Frame: T shape
- Size: 3-Layer 1450mm Length
- Experiment Manuals: 2 sets
- Operation Manual (Hardcopy and Softcopy)
- All manuals are written in English
- Model Answer
- Teaching Manual