ELECTRICAL TRANSMISSION TRAINING SYSTEM

Features:

  1. Input power supply: Three phase-five-line, 415VAC ± 5%
  2. Output power supply: Three phase 0~415V, with voltmeter indication. Single phase 0~250v with voltmeter indication. Three phase 75V/15V/1.8A
  3. DC source: Fixed DC power supply 220V1A, ±15V/2A,±5V/2A,with over current and short circuit protection
  4. Experiment instrument
  • Digital display voltmeter : 500V, 0.5 class
  • Digital display ammeter : 2A, 0.5 class
  • Digital display voltage & current meter: voltage measuring range : 5V/50V/500V;
  • current measuring range; 50mA/500mA/5A, 1.5class.
  • Electrical meter: AC voltage measuring range: 415V phase ,accuracy 0.5 class.
  • AC current measuring range: 5Vphase, accuracy 0.5 class
  • Three phase active power measuring range : ±3.3kW,accuracy 0.5 class
  • Three phase reactive power measuring range : ±3.3kW,accuracy 0.5 class.
  • Power factor measuring range: 0~+1,accuracy 0.5 class
  • Frequency measuring range : 45Hz~65Hz, accuracy 0.05Hz
  • Active/reactive energy measuring range : 99999999, accuracy 1 class

 

Experiment

  1. No load performance
  2. Auto transformer
  3. Series connection of two lines (without capacitor)
  4. Parallel connection of two lines (without capacitor)
  5. Series connection of two lines (with capacitor)
  6. Parallel connection of two lines (with capacitor)
  7. RL circuits in transmission line
  8. RC circuits in transmission line
  9. RLC circuits in transmission line
  10. Measuring power in each line
  11. Transformer Vector Group
  12. Short-circuit performance
  13. Load performance
  14. Zero impedance
  15. Asymmetric load
  16. Transmission Line Model 415V
  17. Electrical Meter
  18. Power Circuit Breaker

Technical Specification:

  1. Three phase transformer TL415kV
  • Transformer for feeding the transmission line model 415V.
  • Scale factor 1:1000 for secondary current and voltage.
  • Nominal Power: 800VA
  • Primary: 3 x 400 V winding with tapping at 230V, can be switched to star or delta connection
  • Delta stabilizing winding can be connected.
  • Secondary: 3 x 380 V winding with tap pings at +5%, -5%, -10%, -15% in star connection, various star Point connections possible
  1. Transmission line model 415kv
  • Measuring steady state operating conditions.
  • Quad bundle 4 x 240/40, with surge impedance 240 and natural load 600 MW, length 360 km.
  • Resistance: 13 Ohm, 8 Ohm, 5 Ohm
  • Inductance: 290 mH, 174 mH, 116 mH Open
  • Capacity: 5 μ F, 3 μ F, 2 μ F
  1. Three phase power supply
  • Fixed and variable AC supplies.
  • Provided with start stop/stop push bottom EMO.
  • Three Phase AC Adjustable Output : 3×0- 415V: 6A
  • Three Phase AC Fixed Output: 240/415V: 10A
  • Power Requirement: 415V, 50Hz
  1. Loads
    Resistive load
  • Compose of three resistances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase.
  • Max Power: 1200 watt
  • Voltage: 415Volt (Star/Delta)

    Inductive load

  • Compose of three inductances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase.
  • Max Power: 900VAR
  • Voltage: 415Volt (Star/Delta)

    Capacitive load – Compose of three capacitances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase.

  • Max Power: 900VAR
  • Voltage : 415Volt (Star/Delta)
  1. Transmission line capacitor TL 415kV
  • 3-phase in star connection, 2.5 μF each, corresponds to 50 % of the operating capacitance of transmission line model 415 kV.
  1. Moving Coil Voltmeter
  • Type: Moving Coil
  • Mode: AC / DC
  • Range: 0…15V, 0…30V
  1. Moving Iron Voltmeter
  • Type: Moving Iron
  • Mode: AC / DC
  • Range: 0…600V
  1. Moving Coil Ammeter
  • Type: Moving Coil
  • Mode: AC / DC
  • Range: 0…100mA, 0…1000mA
  1. Moving Iron Ammeter
  • Type: Moving Iron
  • Mode: AC / DC
  • Range: 0…2.5A
  1. Power meter
  • Range: 0…100 VAR
  • Accuracy: Class 1.5
  1. Single phase synchronous motor
  • Power : 250W
  • Voltage: 240VAC
  • Current:2.2A
  • speed:1725rpm
  1. Three Phase synchronous motor
  • Rated power: 100W
  • Rated voltage:415V(Y)
  • Rated current:0.6A
  • Rated speed: 1400rpm
  • Insulation class: E
  1. Tachometer
  • RPM: 0…..9999rpm
  • Input:AC 240V

 

Accessories:

  1. U-link
  • A unit which is wed to link the unit together
  • 50 units
  1. Safety connecting lead
  • The set consist of 50 leads in 3 different coded colors and lengths chosen to allow the realization of all experiment. – Leads are capable of 32A current safety plugs.
  • Safety terminal socket: 4mm.
  • Red, 90cm (10 units)
  • Yellow, 30cm (10 units)
  • Blue, 60cm (20 units)
  • Black, 90cm (10 units)
  1. Vertical Frame
  • High level: DIN standard A4 with two shelves
  • Material: Aluminium
  • Side Frame: T shape
  • Size: 3-Layer 1450mm Length
  1. Experiment Manuals: 2 sets
  • Operation Manual (Hardcopy and Softcopy)
  • All manuals are written in English
  • Model Answer
  • Teaching Manuals
  1. Stalling Equipment

    used for motor to stall roller

  2. Pulley